Cookies help us deliver our services. By using our services, you agree to our use of cookies. More information

Difference between revisions of "O2k-Main Unit"

From Bioblast
Line 1: Line 1:
{{Product
{{Product
|description=The '''O2k-Main Unit''' is a component of the [[O2k-Core]]. The O2k-Main Unit consists of functionally defined, integral elements, the ([[O2k-Main Basic]], [[O2k-Peltier Temperature Control]], two [[O2k-Electromagnetic Stirrer Twin-Control]] units, two [[O2k-Amperometric OroboPOS Twin-Channel]]s, [[O2k-Barometric Pressure Transducer]]), which cannot be obtained separately.
|description=The '''O2k-Main Unit''' is a component of the [[O2k-Core]]. The O2k-Main Unit consists of functionally defined, integral elements, the [[O2k-Main Basic]], [[O2k-Peltier Temperature Control]], two [[O2k-Electromagnetic Stirrer Twin-Control]] units, two [[O2k-Amperometric OroboPOS Twin-Channel]]s, [[O2k-Barometric Pressure Transducer]], [[O2k-Fluo Control Unit]], which cannot be obtained separately.
|product id=20000
|product id=20000
|product type=O2k-Core
|product type=O2k-Core

Revision as of 16:05, 13 March 2017

                



O2k-Main Unit

O2k-Catalogue

Description The O2k-Main Unit is a component of the O2k-Core. The O2k-Main Unit consists of functionally defined, integral elements, the O2k-Main Basic, O2k-Peltier Temperature Control, two O2k-Electromagnetic Stirrer Twin-Control units, two O2k-Amperometric OroboPOS Twin-Channels, O2k-Barometric Pressure Transducer, O2k-Fluo Control Unit, which cannot be obtained separately.
Product ID 20000
Type O2k-Core
Link O2k-Core
Image


The O2k-Main Unit consists of integral elements, which are not separately available:

TitleDescriptionProduct idProduct image
DatLab-Upgrading to DatLab 6DatLab-Upgrading to DatLab 6: including free follow-up updates for DatLab 6 for the next two years27142-01
O2k-Catalogue: O2k-Modules4#### O2k-Catalogue: O2k-Modules. O2k-Modules can be obtained with the O2k or added later, and can be simply installed by the user.4####4####
O-ring\Viton\12x1 mmO-ring\Viton\12x1 mm, for PVDF or PEEK O2k-Stoppers, box of 4 as spares. Two spare boxes of this product are standard components of the O2k-Assembly Kit (O2k-FluoRespirometer) as well as the O2k-TPP+ ISE-Module and the O2k-NO Amp-Module.Discontinued
Viton O-ring for PVDF Stopper.jpg
TIP2k-Needle Safety SupportTIP2k-Needle Safety Support: for safe storage of TIP2k-needles when not required during the experiment. This item is a standard component of the TIP2k-Module.discontinued
TIP2k-Needle Safety Support overview.JPG



O2k-Series

The O2k is continuously developed further to integrate various innovations. While all O2k instruments have the same high standard for measuring respiration, there are differences with respect to:

The serial number of each O2k is shown on a sticker at the rear of the O2k.

The Series of the O2k is specified as the capital letter in the serial number of the O2k, shown on the label on the rear of the O2k-Main Unit (MiPNet19.18A O2k-start). A serial number B-xxxx or C-xxxx denotes O2k-Series B or C, while G-xxxx denotes an O2k-Series G.



On-line the serial number is displayed in the signal line

With DatLab operating connected to the O2k, the serial number of the O2k is displayed:

  • in the right corner of the status line, besides the DatLab version number (bottom).
On-line the serial number is displayed in the window caption of the O2k-Control window.
  • in the window caption of the O2k-Control window [F7].


Support of O2k-Modules

The O2k (Series E) and higher support all modules. O2k (Series A-D) require the O2k-MultiSensor electronic upgrade. An exception is the application of an NO sensor in a single chamber of the O2k-series A to C.