|description='''Syringe\60 mL\Gas-Injection''', 60 mL, with spacer and stainless steel needle, flat tip, for gas injection into the [[O2k-chamber]].
__TOC__
{{MitoPedia without banner
|abbr=
|description=[[Image:Gas injection syringe.jpg|right|180px]]'''Syringe\60 mL\Gas-Injection''', 60 mL, with spacer and stainless steel needle, flat tip, for gas injection into the [[O2k-chamber]].


This item is a standard component of the [[O2k-Assembly Kit]].
|product id=24430-01
|product type=O2k, O2k-Assembly Kit
|info=[[MiPNet19.18D O2k-Series G and DatLab 6: Calibration]]
|info=[[MiPNet19.18D O2k-Series G and DatLab 6: Calibration]]
|product image=[[Image:Gas injection syringe.jpg|right|180px]]
}}
}}
:::: * For dispatch of the [[Oroboros O2k]], the Gas-Injection Syringe is placed in the [[O2k-Service Box]].


== Technical support ==
:::: * When using one or two O2k instruments, a 10 mL Gas-Injection Syringe might be fully sufficient. Injection of a volume of 1 mL of oxygen or nitrogen gas into the gas phase is enough to change the oxygen concentration in the aqueous phase for reoxygenations (oxygen) or for achieving hypoxia (nitrogen or argon). There is a tendency to inject unnecessarily larger volumes with the 60 mL Gas-Injection Syringe. The smaller syringe, therefore, might be more practical. The stainless steel needle with a spacer can be easily fitted to a 10 mL Gas-Injection Syringe.
:::: * When using one or two O2k instruments, a 10 mL Gas-Injection Syringe might be fully sufficient. Injection of a volume of 1 mL of oxygen or nitrogen gas into the gas phase is enough to change the oxygen concentration in the aqueous phase for reoxygenations (oxygen) or for achieving hypoxia (nitrogen or argon). There is a tendency to inject unnecessarily larger volumes with the 60 mL Gas-Injection Syringe. The smaller syringe, therefore, might be more practical. The stainless steel needle with a spacer can be easily fitted to a 10 mL Gas-Injection Syringe.
{{MitoPedia O2k and high-resolution respirometry
|mitopedia O2k and high-resolution respirometry=O2k hardware, O2k-Open Support, O2k-Respirometry, O2k-FluoRespirometry}}

Revision as of 11:52, 28 October 2020


                  


O2k-Open Support

Syringe\60 mL\Gas-Injection



Template NextGen-O2k.jpg


MitoPedia O2k and high-resolution respirometry: O2k-Open Support 



Description

Gas injection syringe.jpg

Syringe\60 mL\Gas-Injection, 60 mL, with spacer and stainless steel needle, flat tip, for gas injection into the O2k-chamber.


Reference: MiPNet19.18D O2k-Series G and DatLab 6: Calibration


Technical support

* When using one or two O2k instruments, a 10 mL Gas-Injection Syringe might be fully sufficient. Injection of a volume of 1 mL of oxygen or nitrogen gas into the gas phase is enough to change the oxygen concentration in the aqueous phase for reoxygenations (oxygen) or for achieving hypoxia (nitrogen or argon). There is a tendency to inject unnecessarily larger volumes with the 60 mL Gas-Injection Syringe. The smaller syringe, therefore, might be more practical. The stainless steel needle with a spacer can be easily fitted to a 10 mL Gas-Injection Syringe.


MitoPedia O2k and high-resolution respirometry: O2k hardware, O2k-Open Support, O2k-Respirometry, O2k-FluoRespirometry