The '''O2k-Core'''<ref>A PC is required (not included), connecting DatLab to the O2k via a USB port. Minimum requirement: Pentium III, 256 MB, Win 2000™ or Win XP™.</ref> does not include, but fully supports and is required for the add-on Modules of the [[Oxygraph-2k]], such as the [[Titration-Injection microPump|TIP2k]], [[O2k-Fluorescence Module]], [[O2k-TPP+ and Ca2+ Electrode Module (ISE)]], [[O2k-pH Electrode Module]], [[O2k-NO Module]]. | The '''O2k-Core'''<ref>A PC is required (not included), connecting DatLab to the O2k via a USB port. Minimum requirement: Pentium III, 256 MB, Win 2000™ or Win XP™.</ref> does not include, but fully supports and is required for the add-on Modules of the [[Oxygraph-2k]], such as the [[Titration-Injection microPump|TIP2k]], [[O2k-Fluorescence Module]], [[O2k-TPP+ and Ca2+ Electrode Module (ISE)]], [[O2k-pH Electrode Module]], [[O2k-NO Module]]. |
Revision as of 01:19, 24 January 2012
Startup O2k-Respirometer
Description | The O2k-Core (OROBOROS Oxygraph-2k Core) is the Oxygraph-2k including Core-Accessories, complete for basic high-resolution respirometry (HRR). The O2k-Core includes the O2k-Main Unit with stainless steel housing, O2k-Kit, two OroboPOS (polarographic oxygen sensors) and OroboPOS-Kit, DatLab software, the ISS-Integrated Suction System and the Microsyringe-Core Set. The O2k-Core supports all add-on O2k-Modules. |
---|---|
Product ID | 10000-01 |
Type | O2k, O2k-Module, O2k-Core Unit"O2k-Core Unit" is not in the list (O2k, O2k-Module, O2k-Core, O2k-Fluorometer, O2k-Main Unit, O2k-Assembly Kit, OroboPOS, OroboPOS-Service Kit, ISS, TIP2k, ...) of allowed values for the "Product type" property. |
Link | Oxygraph-2k, @OROBOROS, Gnaiger_2008_POS |
Image |
The O2k-Core[1] does not include, but fully supports and is required for the add-on Modules of the Oxygraph-2k, such as the TIP2k, O2k-Fluorescence Module, O2k-TPP+ and Ca2+ Electrode Module (ISE), O2k-pH Electrode Module, O2k-NO Module.
- ↑ A PC is required (not included), connecting DatLab to the O2k via a USB port. Minimum requirement: Pentium III, 256 MB, Win 2000™ or Win XP™.
Catalogue O2k-Core Unit