Startup O2k-Respirometer: Difference between revisions

From Bioblast
No edit summary
Line 1: Line 1:
{{Product
{{Product
|description='''OROBOROS [[Oxygraph-2k]] Core HRR''' (O2k-Core HRR), the complete experimental system for [[HRR|high-resolution respirometry]].
|description='''OROBOROS [[Oxygraph-2k]] Core''' (O2k-Core), the complete experimental system for [[HRR|high-resolution respirometry]].


[http://www.oroboros.at/index.php?id=highresolution Two-chamber high-resolution respirometer] for monitoring oxygen consumption with small amounts of biological material, developed by [[OROBOROS INSTRUMENTS]] in cooperation with [http://www.wgt.at WGT], produced in Austria by WGT, and distributed world-wide by OROBOROS INSTRUMENTS.
[http://www.oroboros.at/index.php?o2k-core Two-chamber high-resolution respirometer] for monitoring oxygen consumption with small amounts of biological material, developed by [[OROBOROS INSTRUMENTS]] in cooperation with [http://www.wgt.at WGT], produced in Austria by WGT, and distributed world-wide by OROBOROS INSTRUMENTS.
|product id=20000-01
|product id=20000-01
|product type=O2k
|product type=O2k
|info=[http://www.oroboros.at/index.php?oxygraph www.oroboros.at], [[Gnaiger_2008_POS]]
|info=[http://www.oroboros.at/index.php?o2k-core www.oroboros.at], [[Gnaiger_2008_POS]]
|product image=[[File:O2k-Core HRR.jpg|300px|link=]]
|product image=[[File:O2k-Core HRR.jpg|300px|link=]]
}}
}}
== O2k-Core HRR ==
== O2k-Core ==


The '''O2k-Core HRR''' or O2k-Core does not include, but fully supports and is required for the O2kβˆ’Modules: Β 
The '''O2k-Core''' does not include, but fully supports and is required for the O2kβˆ’Modules: Β 
::* [[O2k-Fluorescence Module]]
::* [[O2k-Fluorescence Module]]
::* O2k-MultiSensor Modules: [[O2k-TPP+ and Ca2+ Electrode Module (ISE)]], [[O2k-pH Electrode Module]], [[O2k-NO MultiSensor Stoppers]]
::* O2k-MultiSensor Modules: [[O2k-TPP+ and Ca2+ Electrode Module (ISE)]], [[O2k-pH Electrode Module]], [[O2k-NO MultiSensor Stoppers]]
::* [[TIP2k|Titration-Injection microPump TIP2k]]
::* [[TIP2k|Titration-Injection microPump TIP2k]]


The '''O2k-Core HRR''' is a complete experimental system<ref>A PC is required (not included), connecting DatLab to the O2k via a USB port. Minimum requirement: Pentium III, 256 MB, Win 2000β„’ or Win XPβ„’.</ref> ready for standard experiments on high-resolution respirometry.Β  The O2k-Core consists of the following components:
The '''O2k-Core''' is a complete experimental system<ref>A PC is required (not included), connecting DatLab to the O2k via a USB port. Minimum requirement: Pentium III, 256 MB, Win 2000β„’ or Win XPβ„’.</ref> ready for standard experiments on high-resolution respirometry.Β  The O2k-Core consists of the following components:
:1 Peltier thermostat (2 to 47 Β°C; Β±0.001 Β°C)
:1 Peltier thermostat (2 to 47 Β°C; Β±0.001 Β°C)
:2 [[O2k-Chamber|Duran glass chambers]]
:2 [[O2k-Chamber|Duran glass chambers]]

Revision as of 11:11, 1 January 2012

                



Startup O2k-Respirometer

O2k-Catalogue

Description OROBOROS Oxygraph-2k Core (O2k-Core), the complete experimental system for high-resolution respirometry.

Two-chamber high-resolution respirometer for monitoring oxygen consumption with small amounts of biological material, developed by OROBOROS INSTRUMENTS in cooperation with WGT, produced in Austria by WGT, and distributed world-wide by OROBOROS INSTRUMENTS.

Product ID 20000-01
Type O2k
Link www.oroboros.at, Gnaiger_2008_POS
Image File:O2k-Core HRR.jpg

O2k-Core

The O2k-Core does not include, but fully supports and is required for the O2kβˆ’Modules:

The O2k-Core is a complete experimental system[1] ready for standard experiments on high-resolution respirometry. The O2k-Core consists of the following components:

1 Peltier thermostat (2 to 47 Β°C; Β±0.001 Β°C)
2 Duran glass chambers
2 Polarographic oxygen sensors (POS)
2 Amperometric POS channels with variable polarization voltage
2 PVDF stirrers and electromagnetic control
1 Barometric pressure transducer
1 DatLab 4 (Windowsβ„’) data acquision and analysis (USB-stick)
1 Registration fee is waived for an O2k-Workshop
World-wide delivery, shipment, insurance, packing and handling included.
  • 2 Potentiometric channels for ion sensitive electrodes (ISE: TPP+, Ca2+; pH), providing the basis for add-on of the O2k-MultiSensor Modules
  • 2 Amperometric channels with variable polarization voltage, providing the basis for add-on of the O2k-Fluorescence Module or NO (H2S) sensors.

O2k-Core Accessories are included:

1 O2k-Accessory box for POS service, spare membranes
1 Integrated Suction System ISS, to remove medium from the O2k-chamber, stainless steel housing with suction pump, 2-liter waste bottle
6 Titration microsyringes 10 mm3
6 Titration microsyringes 25 mm3
2 Titration microsyringes 50 mm3
3 Spare plungers for 10 mm3 syringe

Notes

  1. ↑ A PC is required (not included), connecting DatLab to the O2k via a USB port. Minimum requirement: Pentium III, 256 MB, Win 2000β„’ or Win XPβ„’.